Bibliographic information

GuidelineInfection prevention and control in the context of coronavirus disease (COVID-19): A guideline
Year of Publication2023
Issuing InstitutionWHO

Recommendation

Maintained

The WHO recommends adhering to the ventilation rate requirements for health-care facilities in the context of COVID-19:

  • 160 l/s/patient for airborne precaution rooms
  • 60 l/s/patient for general wards and outpatient departments

Recommended in favor

Strong

Notes and Remarks

Implementation considerations To provide maximum utility of a ventilation system and greater general dilution of air contaminants throughout any given space, mechanical and natural systems can be used independent of the settings. However, each setting has specific ventilation requirements, defined by national and international regulatory bodies, which differ according to the ventilation objectives. For instance, ventilation systems in health-care facilities are in place as an environmental and engineering control for infection prevention while, in residential buildings, they are mainly intended to create a thermally comfortable indoor environment with acceptable indoor air quality [7].

Adequate ventilation in all patient-care areas plays a key role in helping to prevent and reduce infections.

Ventilation has three basic elements: ventilation rate (m³/hr, l/s or air changes per hour [ACH]), which is the volume of outdoor air that is provided into the space; airflow direction, which is the overall airflow direction in a building and spaces; and air distribution or airflow pattern, which is where the external air should be delivered to each part of the space in an effective and efficient manner.

There are three methods that may be used to ventilate a building: natural, mechanical and hybrid (mixed-mode) ventilation.

The ventilation rate minimum requirements are 160 L/s/patient or 12 air changes per hour (ACH) where aerosol-generating procedures (AGPs) are performed; The ventilation rate minimum requirement is 60 L/s/patient or 6 ACH for other patient-care areas; The airflow direction should be from clean zones to dirty zones; Air should be exhausted directly to the outside, away from air-intake vents, people and animals; Heating, Ventilation and Air Conditioning (HVAC) systems should be operated continuously when people are in the building and should be regularly inspected, maintained and cleaned; AGPs should be performed in rooms equipped with negative-pressure ventilation systems, in keeping with airborne precautions; If no other strategy can be adopted to meet the ventilation rate minimum requirements, consider using a stand-alone air cleaner equipped with a high-efficiency particulate air (HEPA) filter; For additional information on implementing ventilation standards and strategies to improve a health-care facility's ventilation, see Roadmap to improve and ensure good indoor ventilation in the context of COVID-19 [7].

Also Featured In

This recommendation also appears in the following guidelines:

Originally Developed
Guideline

Infection prevention and control in the context of coronavirus disease (‎COVID-19)‎: a living guideline, 9 October 2023.

Year2023
InstitutionWHO